LTQ FT Ultra tm  Linear Ion Trap FTMS 

 

 

LTQ FT UltraTM

 

The Next Generation of Hybrid FTICR Mass Spectrometry

  • Attotomole sensitivity, ppb mass accuracy
  • Resolution >750.000
  • Enhanced dynamic range
  • Parallel detection and fast scanning including MSn
  • Use with ECD, IRMPD, CID and PQD for best possible protein coverage

 

The LTQ FT Ultra combines the most advanced Ion Trap and Fourier Transform Ion Cyclotron Resonance technologies into a single instrument with unprecedented analytical power and versatility. Ultra-high resolution and sensitivity coupled with sub ppm mass accuracy, and MSn are universally available for the toughest applications demanding rigorous structural characterization.

The Ultra Cell - The Heart of the New FTICR

The LTQ FT Ultra mass spectrometer from Thermo Scientific is the next generation hybrid FTICR featuring a novel ICR cell design, the Ultra Cell. This cell design produces enhanced sensitivity and greater dynamic range. The linear excitation characteristics of the cell allow larger cyclotron radii which significantly reduces space charge effects. These performance gains are achieved without the costs and difficulties associated with a higher field magnet.

  • Attomole sensitivity
  • Widest dynamic range ( > 4.000)
  • ppb mass accuracy
  • Resolution > 750.000

Thermo Fisher Scientific is the undisputed leader in hybrid mass spectrometry technology. The new LTQ FT Ultra is built on the proven combination of Thermo Scientific's linear ion trap and FTICR platform, featuring:

  • Automatic Gain Control – concentration independent ppb mass accuracy with space charge control
  • Parrallel Acquisition – unmatched data dependant acquisition speed
  • ECD and IRMPD – detailed characterization of peptides and proteins
  • Fast Scan Rate with High Resolution – compatible with LC timescale
  • Automated Optimization and Acquisition – simplified operation

ATTOMOLE SENSITIVITY
For identification of low abundance peptides

50 attomole on column On-line nano-LC-MS/MS of a 5 protein mix digest (50 attomole each on column, 30 min gradient). Data analysed with BioWorks 3.3. All proteins found with at least 2 peptides, high Xcorr and high peptide probability.

Maintain mass accuracy over a
WIDER DYNAMIC RANGE

Concentration independent mass accuracy in infusion or under LC conditions. Detect and correctly identify low abundant co-eluting species.
 


Please ask us for a quote or just ask a question, no obligation

Quote   or  Question
 
Select the instrument you are interested in

           

Enter additional comments or questions in the space provided below:

Tell us how to get in touch with you:

(This information will only be made available to Thermo Fisher Scientific)

Name
E-mail
Tel
Company or Institution
 

Address:

 
Street  
City  
Country  
Zip Code  


 

Please contact me as soon as possible regarding this matter.


home | terms of use (disclaimer) 
Copyright © 2000-2008  IonSource, LLC  All rights reserved. 
Last updated:  Tuesday, May 20, 2008 10:39:16 AM

 

 

 

 

 

 

 

 

 

 

 

 

 

Hit Counter